{ "elements": [ { "type": "Label", "caption": "Main" }, { "type": "ValidationTextBox", "name": "devName", "caption": "Name" }, { "type": "NumberSpinner", "name": "devTime", "caption": "Refreshtime" }, { "type": "Label", "caption": "Mqtt Properties" }, { "type": "SelectInstance", "name": "mqttGwId", "caption": "Mqtt Gateway", "validModules":["{C6D2AEB3-6E1F-4B2E-8E69-3A1A00246850}"] }, { "type": "SelectInstance", "name": "modGwId", "caption": "Modbus Gateway", "validModules":["{A5F663AB-C400-4FE5-B207-4D67CC030564}"] }, { "type": "ValidationTextBox", "name": "mqttPrefix", "caption": "Mqtt-Prefix e.g. Milesight01 (/uplink/EUI and /downlink/EUI is autm. added)" }, { "type": "ValidationTextBox", "name": "devEui", "caption": "Device EUI (as Suffix on MQTT Topic)" }, { "type": "Label", "caption": "Modbus Actualvalus to Controler:" }, { "type": "NumberSpinner", "name": "modFcWriteActValues", "caption": "Functioncode Write actual Values", "value": 16}, { "type": "NumberSpinner", "name": "modFcReadActValues", "caption": "Functioncode Read Actual Values", "value": 3}, { "type": "NumberSpinner", "name": "modAmbient_Temperature", "caption": "Modbusadress Ambient_Temperature" }, { "type": "NumberSpinner", "name": "modCurrent_Valve_Position", "caption": "Modbusadress Current_Valve_Position" }, { "type": "NumberSpinner", "name": "modCalibration_OK", "caption": "Modbusadress Calibration_OK" }, { "type": "NumberSpinner", "name": "modFlow_Temperature", "caption": "Modbusadress Flow_Temperature (Float)" }, { "type": "NumberSpinner", "name": "modHarvesting_Active", "caption": "Modbusadress Harvesting_Active" }, { "type": "NumberSpinner", "name": "modMotor_Error", "caption": "Modbusadress Motor_Error" }, { "type": "NumberSpinner", "name": "modStorage_Fully_Charged", "caption": "Modbusadress Storage_Fully_Charged" }, { "type": "NumberSpinner", "name": "modStorage_Voltage", "caption": "Modbusadress Setpoint" }, { "type": "NumberSpinner", "name": "modRSSI", "caption": "Modbusadress RSSI" }, { "type": "NumberSpinner", "name": "modUsed_Temperature", "caption": "Modbusadress Used_Temperature" }, { "type": "NumberSpinner", "name": "modUser_Value", "caption": "Modbusadress User_Value" }, { "type": "Label", "caption": "Modbus Setpointvalus from Controler:" }, { "type": "NumberSpinner", "name": "modFcReadSetpoints", "caption": "Functioncode", "value": 4}, { "type": "NumberSpinner", "name": "modUsermode", "caption": "Modbusadress Usermode (1 Ambienttemp | 2 Flowtemp | 3 Valveposition)", "width": "40%"}, { "type": "NumberSpinner", "name": "modSetpoint", "caption": "Modbusadress Setpoint" }, { "type": "NumberSpinner", "name": "modRoomtemp", "caption": "Modbusadress Roomtemp" }, { "type": "NumberSpinner", "name": "modSafetymode", "caption": "Modbusadress Safetymode (1 Safety AmbientTemp | 2 Safety Flowtemp | 3 Safety Valvepos)", "width": "40%"}, { "type": "NumberSpinner", "name": "modSafetySetpoint", "caption": "Modbusadress Safety Setpoint" }, { "type": "NumberSpinner", "name": "modComIntervall", "caption": "Modbusadress Comintervall (only 5/10/60/120/480 !!!)" }, { "type": "NumberSpinner", "name": "modRefRun", "caption": "Modbusadress Reference Run" } ], "actions": [ ], "status": [ ] }