fix: support Symcon numeric dimmers and independent blind slat controls

This commit is contained in:
jhartworks committed 2026-11-09 15:24:59 +01:00
1 parent b934f78b9a
commit 24188f96f7
36 files changed
+1105 -683

No files matched your search

+2
View File
@@ -18,6 +18,8 @@ All notable changes to NextFloor, newest first. Every release lists what is **Ad
### Fixed
- **IP-Symcon dimmers and venetian blinds:** Numeric variables can be explicitly linked as dimmers or blind controls independently of inferred names. Native integer/float ranges and steps are respected in both directions. Separate blind-height and slat-position variables can be selected in the object tree and controlled independently in the room panel and quick menu; dimmer sliders stay available while off.
- **IP-Symcon KNX room temperatures:** Current Symcon presentation units are read alongside legacy profiles. Numeric temperature variables remain selectable and readable even when a parent name caused an actuator classification; saved mappings stay intact.
- **IP-Symcon “HTTP 200” / output-buffer overflow:** Large API responses use bounded response chunks instead of exceeding the kernel's 1 MiB output limit. The full variable/object tree, packs, plans, images and backups are reassembled without data loss, polling cannot overlap, and malformed responses receive a useful error message.