fix: support Symcon numeric dimmers and independent blind slat controls
This commit is contained in:
1 parent
b934f78b9a
commit
24188f96f7
36 files changed
+1105
-683
No files matched your search
@@ -18,6 +18,8 @@ All notable changes to NextFloor, newest first. Every release lists what is **Ad
|
||||
|
||||
### Fixed
|
||||
|
||||
- **IP-Symcon dimmers and venetian blinds:** Numeric variables can be explicitly linked as dimmers or blind controls independently of inferred names. Native integer/float ranges and steps are respected in both directions. Separate blind-height and slat-position variables can be selected in the object tree and controlled independently in the room panel and quick menu; dimmer sliders stay available while off.
|
||||
|
||||
- **IP-Symcon KNX room temperatures:** Current Symcon presentation units are read alongside legacy profiles. Numeric temperature variables remain selectable and readable even when a parent name caused an actuator classification; saved mappings stay intact.
|
||||
|
||||
- **IP-Symcon “HTTP 200” / output-buffer overflow:** Large API responses use bounded response chunks instead of exceeding the kernel's 1 MiB output limit. The full variable/object tree, packs, plans, images and backups are reassembled without data loss, polling cannot overlap, and malformed responses receive a useful error message.
|
||||
|
||||
Reference in new issue