56 lines
3.7 KiB
JSON
56 lines
3.7 KiB
JSON
{
|
|
"elements":
|
|
[
|
|
{ "type": "Label", "caption": "Main" },
|
|
{ "type": "ValidationTextBox", "name": "devName", "caption": "Name" },
|
|
{ "type": "NumberSpinner", "name": "devTime", "caption": "Refreshtime" },
|
|
|
|
{ "type": "Label", "caption": "Mqtt Properties" },
|
|
{ "type": "SelectInstance", "name": "mqttGwId", "caption": "Mqtt Gateway", "validModules":["{C6D2AEB3-6E1F-4B2E-8E69-3A1A00246850}"] },
|
|
{ "type": "SelectInstance", "name": "modGwId", "caption": "Modbus Gateway", "validModules":["{A5F663AB-C400-4FE5-B207-4D67CC030564}"] },
|
|
|
|
{ "type": "ValidationTextBox", "name": "mqttPrefix", "caption": "Mqtt-Prefix e.g. Milesight01 (/uplink/EUI and /downlink/EUI is autm. added)" },
|
|
{ "type": "ValidationTextBox", "name": "devEui", "caption": "Device EUI (as Suffix on MQTT Topic)" },
|
|
|
|
|
|
{ "type": "Label", "caption": "Modbus Actualvalus to Controler:" },
|
|
{ "type": "NumberSpinner", "name": "modFcWriteActValues", "caption": "Functioncode Write actual Values", "value": 16},
|
|
{ "type": "NumberSpinner", "name": "modFcReadActValues", "caption": "Functioncode Read Actual Values", "value": 3},
|
|
|
|
{ "type": "NumberSpinner", "name": "modAmbient_Temperature", "caption": "Modbusadress Ambient_Temperature" },
|
|
{ "type": "NumberSpinner", "name": "modCurrent_Valve_Position", "caption": "Modbusadress Current_Valve_Position" },
|
|
{ "type": "NumberSpinner", "name": "modCalibration_OK", "caption": "Modbusadress Calibration_OK" },
|
|
|
|
{ "type": "NumberSpinner", "name": "modFlow_Temperature", "caption": "Modbusadress Flow_Temperature (Float)" },
|
|
{ "type": "NumberSpinner", "name": "modHarvesting_Active", "caption": "Modbusadress Harvesting_Active" },
|
|
|
|
{ "type": "NumberSpinner", "name": "modMotor_Error", "caption": "Modbusadress Motor_Error" },
|
|
{ "type": "NumberSpinner", "name": "modStorage_Fully_Charged", "caption": "Modbusadress Storage_Fully_Charged" },
|
|
{ "type": "NumberSpinner", "name": "modStorage_Voltage", "caption": "Modbusadress Setpoint" },
|
|
|
|
{ "type": "NumberSpinner", "name": "modRSSI", "caption": "Modbusadress RSSI" },
|
|
{ "type": "NumberSpinner", "name": "modUsed_Temperature", "caption": "Modbusadress Used_Temperature" },
|
|
{ "type": "NumberSpinner", "name": "modUser_Value", "caption": "Modbusadress User_Value" },
|
|
|
|
{ "type": "Label", "caption": "Modbus Setpointvalus from Controler:" },
|
|
{ "type": "NumberSpinner", "name": "modFcReadSetpoints", "caption": "Functioncode", "value": 4},
|
|
{ "type": "NumberSpinner", "name": "modUsermode", "caption": "Modbusadress Usermode (1 Ambienttemp | 2 Flowtemp | 3 Valveposition)", "width": "40%"},
|
|
{ "type": "NumberSpinner", "name": "modSetpoint", "caption": "Modbusadress Setpoint" },
|
|
{ "type": "NumberSpinner", "name": "modRoomtemp", "caption": "Modbusadress Roomtemp" },
|
|
{ "type": "NumberSpinner", "name": "modSafetymode", "caption": "Modbusadress Safetymode (1 Safety AmbientTemp | 2 Safety Flowtemp | 3 Safety Valvepos)", "width": "40%"},
|
|
{ "type": "NumberSpinner", "name": "modSafetySetpoint", "caption": "Modbusadress Safety Setpoint" },
|
|
{ "type": "NumberSpinner", "name": "modComIntervall", "caption": "Modbusadress Comintervall (only 5/10/60/120/480 !!!)" },
|
|
{ "type": "NumberSpinner", "name": "modRefRun", "caption": "Modbusadress Reference Run" }
|
|
|
|
|
|
|
|
],
|
|
"actions":
|
|
[
|
|
|
|
],
|
|
"status":
|
|
[
|
|
|
|
]
|
|
} |